Air Conditioners

Robin Aire Heating & Cooling, Inc.

HS/HP29 Air Conditioners and Heat Pumps

Muscular performance and rugged durability.

Features and Benefits

Efficient operation
  • Efficiency ratings of up to 11.50 SEER and 8.10 HSPF – can save you hundreds of dollars a year, compared to a standard heat pump and air conditioner.
Quiet and efficient operation
  • Scroll Compressor – provides smooth, efficient and quiet operation.

  • High-Efficiency Outdoor Coil – provides exceptional heat transfer and low air resistance for high-efficiency operation.

  • Quiet, Direct-Drive Fan – precision-balanced, direct-drive fan is designed to run slower for an enhanced level of quiet operation.
Easy installation and maintenance
  • Brass Service Valves – isolate the refrigeration system in outdoor units and allow for simple access.

  • Full-Perimeter Base Rails – provide structural integrity during unit transport and movement. Forklift slots and lifting holes help speed up tasks such as moving and lifting the unit when on the job site.

  • Control Box – slide-out control box with hinged panel access makes this a convenient and time-saving feature during installation and maintenance (15- and 20-ton AC models only).
Reliable performance
  • Fan Guard – heavy-duty guard increases safety.

  • Fan Motor – features a fully enclosed design with a rain shield to provide maximum protection from weather, dust, corrosion and moisture.

  • Corrosion-Resistant Cabinet – G-90 galvanized steel under a two-layer painted surface protects against rust and corrosion.

  • High-Pressure Switch – extends the life of the unit by providing a safeguard against excessive pressure.

  • Loss-of-Charge Switch – protects compressor from damage due to low refrigerant charge conditions.

  • Crankcase Heaters – protect the compressor against refrigerant migration that can occur during low ambient operations.

  • Multiple Refrigeration Circuits – separate refrigeration circuits and scroll compressors provide help to ensure against the loss of a compressor or refrigeration circuit for continued operation and cooling capability.

  • Solid-State Defrost Control – monitors the condition of the coil. Quickly and efficiently clears the build-up of frost on the coil.

  • Minimum Run Time Control – prevents compressor short-cycling and helps assure oil return to the compressor.

  • Enhanced Coil Guard – protects the condenser coil, maintaining the efficiency of the unit. Heavy-gauge steel construction and non-corrosive PVC coating assure long-lasing coil protection.

  • High-Capacity Liquid Line Drier – protects the refrigeration system from moisture and dirt (available on heat pump units only).

  • Low Ambient Operation – standard low ambient operation to 0ºF increases unit operating range to cover a wide range of operating scenarios throughout the year.
Warranty
  • 5-Year Limited Warranty on compressor.

  • 1-Year Limited Warranty on covered components.

HS/HP29 3- TO 5-TON

Features and Benefits

Improved reliability
  • Compressor Low Ambient Cutoff – prevents compressor operation when outdoor temperature is below 35°F.

  • Compressor Time-off Control – improves compressor reliability by preventing short-cycling and allowing the compressor to start in an unloaded condition.

  • Loss-of-Charge Kit – protects compressor from damage due to low refrigerant charge conditions.

  • High-Pressure Switch Kit – protects the system from high-pressure conditions that can result from a fan failure or a blocked or dirty coil.

  • Hail Guards – constructed of louvered heavy-gauge steel, hail guards surround unit on all four sides and prevent damage to the coil.

  • Freezestat – prevents system failure in cold conditions by cycling the compressor off when the suction line temperature falls below the setpoint.

  • Crankcase Heater – protects the compressor against refrigerant migration that can occur during low ambient temperatures.
Application solutions
  • Low Ambient Control to 30°F – allows for unit operation down to 30°F.
Quiet and efficient operation
  • Compressor Sound Cover – reinforced vinyl cover with fiberglass insulation helps lower operating sound levels.

  • Mild Weather Kits – allow heat pump units to operate in conditions up to 75ºF (heat pump units only)
Easy installation and maintenance
  • Mounting Base – extremely durable, high-density polyethylene structural material is lightweight, sturdy and provides a permanent foundation for outdoor units.

  • Unit Stand-Off Kit – raises unit off the mounting surface and away from potentially damaging moisture.

  • Refrigerant Line Kits – refrigerant lines are shipped cleaned, dried, pressurized and sealed at the factory for easy installation.

HS/HP29 6- TO 20-TON

Features and Benefits

Improved reliability
  • Hail Guards – constructed of louvered heavy-gauge steel, hail guards surround unit on all four sides and prevent damage to the coil
Application solutions
  • Hot Gas Bypass – provides reduced capacity control for increased performance over a wide range of operating scenarios.