L Series® (LG, LC, LH) Rooftop Units
Designed to achieve a low total cost of ownership.
Features and Benefits
Efficient Operation
- Standard
and high efficiencies available in 3- to 30-tons, up to 13.25 SEER, up to 12.2 EER and up to 14.7 IPLV.
- ASHRAE 90.1 compliant.
- ENERGY STAR® qualified.*
Application
solutions for efficient operation
- Integrated
Modular Controller – provides centralized control and fast, simple troubleshooting to reduce operation and service cost.
- Humiditrol® Dehumidification System – helps control humidity levels, improving comfort and indoor air quality.
- Multiple Compressors – allow the unit to provide efficient cooling with four-cooling-stage
capability.
- Thermostatic Expansion
Valves – provide peak cooling performance across the entire application range for better comfort.
- Variable-Frequency Drives – provides variable air volume
unit operation to meet a variety of zoning system needs.
Quick, easy installation and maintenance
- Independent Motor Mount – allows for easy, efficient access without removing top panel.
- Full-Perimeter Base Rail –
provides greater structural integrity so the unit is easier to handle when rigging and transporting.
- Slab Coil – permits faster, more thorough coil cleaning.
- Hinged Toolless Access Panels –
provide quick access to components and protect panels and roof from damage during service.
- Isolated Compressor Compartment – allows performance check
during normal compressor operation without disrupting airflow.
- Slide-Out Blower Deck – improves access for belt, blower and motor, reducing maintenance time.
Reliable performance
- Corrosion-Resistant Cabinet – G-90
galvanized steel cabinet under a two-layer painted surface protects against rust and corrosion.
- High- and Low-Pressure Switches – safeguard compressor from
extreme operating conditions and unnecessary wear and tear.
Factory installed options
- Humiditrol dehumidification system
- R-22 or R-410A refrigerant
- Low- or high-static motors and drives
- NEMA high-efficiency supply fan motors
- Coil corrosion protection
- Refrigerant service valves
- Stainless
steel heat exchanger
- HACR breakers
- Variable-air-volume bypass (select
models)
- Variable-frequency drives
on supply fan (select models)
Field-installed
accessories
- Standard and
high static power exhaust fans (select models)
- Energy Recovery Systems (wheels)
- 14" and 24" Curbs
- Combustion
air intake and exhaust extensions
- LPG
conversion
- Coil guards
- Hail guards
- Humidity sensor
- CO2 sensor
- Temperature
sensor
- UVC germicidal lamp
Factory options or field accessories
- Economizers
- Outdoor air dampers
- Disconnects
- GFIs
- Barometric relief
- Standard powered exhaust (select models)
- Supply and return smoke detectors
- Dirty filter switch
- MERV 8, 11 and 15 filters
- Fresh air tempering
Warranty
- 15-Year Limited Warranty on stainless steel
heat exchanger.
- 10-Year Limited
Warranty on aluminized heat exchanger.
- 5-Year
Limited Warranty on compressor.
- 3-Year
Limited Warranty on Integrated Modular Controller.
- 1-Year Limited Warranty on covered components.
*Proper sizing and installation of equipment are critical to achieve optimal performance. Split system air
conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor
for details or visit www.energystar.gov.
T-Class™ (TG, TC, TH) Rooftop Units
True performance backed by rugged durability.
Features and Benefits
Efficient
operation
- Standard- and
high-efficiency available in 2- to 25-ton, up to 13.5 SEER, up to 11.0 EER and 11.4 IPLV.
- 2- to 5-ton models meet ASHRAE 90.1 regulations and NAECA regulations
- 6- to 25-ton models meet ASHRAE
90.1 regulations.
- ENERGY STAR®
qualified.*
Quick, easy installation
and maintenance
- Large-Access
Panels – remove easily for quick access to the compressor, refrigerant components and electrical controls.**
- Full-Perimeter Base Rail – provides
greater structural integrity so the unit is easier to handle when rigging and transporting.
- Isolated Compressor Compartment – allows performance check
during normal compressor operation without disrupting airflow.
- Fork Slots on Three Sides – easy to pick up and transport units from almost any angle.
- Slide-Out Blower Deck – improves
service access for blower and motor.†
Reliable
performance
- Corrosion-Resistant
Cabinet – G-90 galvanized steel cabinet under a two-layer surface protects against rust and corrosion.
- Multiple Compressor Circuits – allow the unit to provide
efficient heating and cooling.†
- Independent
Motor Mount – allows for easy, efficient access without removing top panel.
- Direct Spark Ignition – electronic ignition eliminates standing pilot and enhances efficiency
(packaged gas/electric model only).
- Pre-defined
Supply Fan Motor/Drive Combinations – make selecting components to meet static and airflow requirements quick and easy.
- Thermostatic Expansion Valves –
provide peak cooling performance across the entire application range.
Field-installed accessories
- Non-Powered GFI
- HACR
circuit breaker
- Disconnects
- High pressure switches
- Economizers with sensible control or single
or dual enthalpy control
- Barometric
relief dampers
- Manual outdoor
air dampers (25%)
- Motorized outdoor
air dampers
- Electric heat
- 50% constant volume powered exhaust
fan‡
- CO2 sensor
- Return and supply air smoke detectors
- Low ambient kit
- Hail guards
- Coil guards
- MERV
11 Filter
- Link to the L Connection®
Network line of commercial controls with an optional Network Thermostat Controller
- LPG Conversion Kit (Gas/Electric only)
- -60°F cold weather kit (Gas/Electric only)
- Combustion air intake or flue exhaust extensions (Gas/Electric only)
- High- and low-static drive kits
- Blower proving switch
- Dirty filter switch
Warranty
- 15-Year Limited Warranty on stainless steel
gas heat exchanger.
- 10-Year Limited
Warranty on aluminized gas heat exchanger.
- 5-Year
Limited Warranty on compressor.
- 1-Year
Limited Warranty on covered components.
*Proper
sizing and installation of equipment are critical to achieve optimal performance. Split system air conditioners and heat pumps
must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.
**Hinged door upgrade available as a factory built-to-order option
† Available on 7.5- to 25-ton
models
‡ Not available on 2- and 2.5-ton models
|
|
|