L Series® (LG, LC, LH) Rooftop Units

Designed to achieve a low total cost of ownership.

Features and Benefits

Efficient Operation
  • Standard and high efficiencies available in 3- to 30-tons, up to 13.25 SEER, up to 12.2 EER and up to 14.7 IPLV.

  • ASHRAE 90.1 compliant.

  • ENERGY STAR® qualified.*
Application solutions for efficient operation
  • Integrated Modular Controller – provides centralized control and fast, simple troubleshooting to reduce operation and service cost.

  • Humiditrol® Dehumidification System – helps control humidity levels, improving comfort and indoor air quality.

  • Multiple Compressors – allow the unit to provide efficient cooling with four-cooling-stage capability.

  • Thermostatic Expansion Valves – provide peak cooling performance across the entire application range for better comfort.

  • Variable-Frequency Drives – provides variable air volume unit operation to meet a variety of zoning system needs.
Quick, easy installation and maintenance
  • Independent Motor Mount – allows for easy, efficient access without removing top panel.

  • Full-Perimeter Base Rail – provides greater structural integrity so the unit is easier to handle when rigging and transporting.

  • Slab Coil – permits faster, more thorough coil cleaning.

  • Hinged Toolless Access Panels – provide quick access to components and protect panels and roof from damage during service.

  • Isolated Compressor Compartment – allows performance check during normal compressor operation without disrupting airflow.

  • Slide-Out Blower Deck – improves access for belt, blower and motor, reducing maintenance time.
Reliable performance
  • Corrosion-Resistant Cabinet – G-90 galvanized steel cabinet under a two-layer painted surface protects against rust and corrosion.

  • High- and Low-Pressure Switches – safeguard compressor from extreme operating conditions and unnecessary wear and tear.
Factory installed options
  • Humiditrol dehumidification system

  • R-22 or R-410A refrigerant

  • Low- or high-static motors and drives

  • NEMA high-efficiency supply fan motors

  • Coil corrosion protection

  • Refrigerant service valves

  • Stainless steel heat exchanger

  • HACR breakers

  • Variable-air-volume bypass (select models)

  • Variable-frequency drives on supply fan (select models)
Field-installed accessories
  • Standard and high static power exhaust fans (select models)

  • Energy Recovery Systems (wheels)

  • 14" and 24" Curbs

  • Combustion air intake and exhaust extensions

  • LPG conversion

  • Coil guards

  • Hail guards

  • Humidity sensor

  • CO2 sensor

  • Temperature sensor

  • UVC germicidal lamp
Factory options or field accessories
  • Economizers

  • Outdoor air dampers

  • Disconnects

  • GFIs

  • Barometric relief

  • Standard powered exhaust (select models)

  • Supply and return smoke detectors

  • Dirty filter switch

  • MERV 8, 11 and 15 filters

  • Fresh air tempering
Warranty
  • 15-Year Limited Warranty on stainless steel heat exchanger.

  • 10-Year Limited Warranty on aluminized heat exchanger.

  • 5-Year Limited Warranty on compressor.

  • 3-Year Limited Warranty on Integrated Modular Controller.

  • 1-Year Limited Warranty on covered components.
*Proper sizing and installation of equipment are critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.

Robin Aire Heating & Cooling, Inc.

T-Class™ (TG, TC, TH) Rooftop Units

True performance backed by rugged durability.

Features and Benefits

Efficient operation
  • Standard- and high-efficiency available in 2- to 25-ton, up to 13.5 SEER, up to 11.0 EER and 11.4 IPLV.

  • 2- to 5-ton models meet ASHRAE 90.1 regulations and NAECA regulations

  • 6- to 25-ton models meet ASHRAE 90.1 regulations.

  • ENERGY STAR® qualified.*
Quick, easy installation and maintenance
  • Large-Access Panels – remove easily for quick access to the compressor, refrigerant components and electrical controls.**

  • Full-Perimeter Base Rail – provides greater structural integrity so the unit is easier to handle when rigging and transporting.

  • Isolated Compressor Compartment – allows performance check during normal compressor operation without disrupting airflow.

  • Fork Slots on Three Sides – easy to pick up and transport units from almost any angle.

  • Slide-Out Blower Deck – improves service access for blower and motor.†
Reliable performance
  • Corrosion-Resistant Cabinet – G-90 galvanized steel cabinet under a two-layer surface protects against rust and corrosion.

  • Multiple Compressor Circuits – allow the unit to provide efficient heating and cooling.†

  • Independent Motor Mount – allows for easy, efficient access without removing top panel.

  • Direct Spark Ignition – electronic ignition eliminates standing pilot and enhances efficiency (packaged gas/electric model only).

  • Pre-defined Supply Fan Motor/Drive Combinations – make selecting components to meet static and airflow requirements quick and easy.

  • Thermostatic Expansion Valves – provide peak cooling performance across the entire application range.
Field-installed accessories
  • Non-Powered GFI

  • HACR circuit breaker

  • Disconnects

  • High pressure switches

  • Economizers with sensible control or single or dual enthalpy control

  • Barometric relief dampers

  • Manual outdoor air dampers (25%)

  • Motorized outdoor air dampers

  • Electric heat

  • 50% constant volume powered exhaust fan‡

  • CO2 sensor

  • Return and supply air smoke detectors

  • Low ambient kit

  • Hail guards

  • Coil guards

  • MERV 11 Filter

  • Link to the L Connection® Network line of commercial controls with an optional Network Thermostat Controller

  • LPG Conversion Kit (Gas/Electric only)

  • -60°F cold weather kit (Gas/Electric only)

  • Combustion air intake or flue exhaust extensions (Gas/Electric only)

  • High- and low-static drive kits

  • Blower proving switch

  • Dirty filter switch
Warranty
  • 15-Year Limited Warranty on stainless steel gas heat exchanger.

  • 10-Year Limited Warranty on aluminized gas heat exchanger.

  • 5-Year Limited Warranty on compressor.

  • 1-Year Limited Warranty on covered components.
*Proper sizing and installation of equipment are critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.

**Hinged door upgrade available as a factory built-to-order option

† Available on 7.5- to 25-ton models

‡ Not available on 2- and 2.5-ton models